ECEdge

Exam: GATE 2027 exams are on 6, 7, 13, 14, 20 and 21 February 2027. Official GATE 2027 site

Microstrip impedance calculator (50 Ω trace width)

Calculate a microstrip trace’s characteristic impedance, and the width needed for 50 Ω or any target on your board.

Microstrip impedance

The characteristic impedance of a trace over a ground plane. It also works out the width needed for the target impedance you enter.

Hammerstad–Wheeler formulas; copper thickness ignored

How it works

  • A microstrip is a trace on the outer layer with a ground plane underneath.
  • Its impedance depends on the ratio of width to height (w/h) and the board’s dielectric constant εr.
  • This uses the Hammerstad–Wheeler formulas, accurate to a few percent for thin copper.

Worked example

FR4 (εr = 4.4), 1.6 mm thick, w = 3 mm: effective εr ≈ 3.33 and Z₀ ≈ 50.8 Ω. So a 50 Ω line on a standard 2-layer board is about 3 mm wide.

Common questions

Why are 50 Ω lines so wide on a 2-layer board?

Because the ground is 1.6 mm away. On a 4-layer board the ground layer is about 0.2 mm below, so a 50 Ω line is only about 0.35–0.4 mm wide.

Which εr should I use for FR4?

Between 4.2 and 4.6, depending on the material and frequency. Your PCB maker lists the exact value for their stack-up.

More calculators