Control systems

Transfer functions, block diagrams and signal flow graphs, time response, steady-state error, Routh, Nyquist, Bode and root locus, compensators, PID and state space.

  • 36 formulas
  • 8 topics

The PDF is A4 portrait, ready to print or keep on your phone.

6.1Transfer functions

Negative feedback
T(s) = G(s)/(1 + G(s)H(s))
(6.1.1)
Mason’s gain formula
T = (1/Δ)Σ PₖΔₖ; Δ = 1 − Σ loops + Σ non-touching pairs − Σ triples …
(6.1.2)
Sensitivity
SGT = (∂T/T)/(∂G/G) = 1/(1 + GH)
(6.1.3)

6.2Time response

Second-order system
T(s) = ωₙ²/(s² + 2ζωₙs + ωₙ²)
(6.2.1)
Poles
s = −ζωₙ ± jωₙ√(1 − ζ²); ωd = ωₙ√(1 − ζ²)
(6.2.2)
Rise time
tr = (π − θ)/ωd, θ = cos⁻¹ζ
(6.2.3)
Peak time
tp = π/ωd
(6.2.4)
Peak overshoot
Mp = e−πζ/√(1 − ζ²)
(6.2.5)
Settling time
ts ≈ 4/(ζωₙ) (2%); 3/(ζωₙ) (5%)
(6.2.6)
First-order system
Time constant τ; reaches 63.2% at τ; settles in ≈ 4τ
(6.2.7)

6.3Steady-state error (unity feedback)

Error constants
Kp = lims→0 G; Kv = lim sG; Ka = lim s²G
(6.3.1)
Errors
Step: 1/(1 + Kp); ramp: 1/Kv; parabola: 1/Ka
(6.3.2)
System type
Type = number of open-loop poles at the origin
(6.3.3)

6.4Stability

Routh–Hurwitz
Sign changes in the first column = number of right half-plane poles
(6.4.1)
Nyquist
Z = P − N (N = anticlockwise encirclements of −1 + j0, P = open-loop RHP poles); stable iff Z = 0
(6.4.2)
Gain margin
GM = 1/|GH(jωpc)| at phase −180°; GM (dB) = −20 log|GH(jωpc)|
(6.4.3)
Phase margin
PM = 180° + ∠GH(jωgc) at |GH| = 1
(6.4.4)
PM and damping
PM ≈ 100ζ degrees (ζ < 0.7)
(6.4.5)

6.5Root locus

Start and end
Starts at open-loop poles (K = 0), ends at zeros or infinity
(6.5.1)
Real axis
Locus lies left of an odd number of real poles + zeros
(6.5.2)
Asymptotes
Angles (2q + 1)180°/(P − Z); centroid σ = (Σ poles − Σ zeros)/(P − Z)
(6.5.3)
Breakaway point
dK/ds = 0
(6.5.4)
Angle of departure
180° − Σ∠(from other poles) + Σ∠(from zeros)
(6.5.5)

6.6Frequency response

Bode slopes
Each pole −20 dB/decade and −90°; each zero +20 dB/decade and +90°
(6.6.1)
Resonant peak
Mr = 1/(2ζ√(1 − ζ²)) at ωr = ωₙ√(1 − 2ζ²) (ζ < 0.707)
(6.6.2)
Bandwidth
ωb = ωₙ√(1 − 2ζ² + √(4ζ⁴ − 4ζ² + 2))
(6.6.3)

6.7Compensators and PID

Lead compensator
(1 + aTs)/(1 + Ts), a > 1; max lead sin φₘ = (a − 1)/(a + 1) at ωₘ = 1/(T√a)
(6.7.1)
Effects
Lead: more phase margin, faster response; lag: smaller steady-state error
(6.7.2)
PID controller
C(s) = Kp + Ki/s + Kd s
(6.7.3)
PID roles
P speeds up; I removes steady-state error; D adds damping
(6.7.4)

6.8State space

Model
ẋ = Ax + Bu; y = Cx + Du
(6.8.1)
Transfer function
T(s) = C(sI − A)⁻¹B + D; poles = eigenvalues of A
(6.8.2)
State transition matrix
Φ(t) = eAt = L⁻¹{(sI − A)⁻¹}
(6.8.3)
Solution
x(t) = Φ(t)x(0) + ∫₀ᵗ Φ(t − τ)Bu(τ)dτ
(6.8.4)
Controllability
rank[B AB … Aⁿ⁻¹B] = n
(6.8.5)
Observability
rank[C; CA; …; CAⁿ⁻¹] = n
(6.8.6)