GATE 2027 EC, Section 6
Control systems
Transfer functions, block diagrams and signal flow graphs, time response, steady-state error, Routh, Nyquist, Bode and root locus, compensators, PID and state space.
- 36 formulas
- 8 topics
The PDF is A4 portrait, ready to print or keep on your phone.
6.1Transfer functions
- Negative feedback
- T(s) = G(s)/(1 + G(s)H(s))
- (6.1.1)
- Mason’s gain formula
- T = (1/Δ)Σ PₖΔₖ; Δ = 1 − Σ loops + Σ non-touching pairs − Σ triples …
- (6.1.2)
- Sensitivity
- SGT = (∂T/T)/(∂G/G) = 1/(1 + GH)
- (6.1.3)
6.2Time response
- Second-order system
- T(s) = ωₙ²/(s² + 2ζωₙs + ωₙ²)
- (6.2.1)
- Poles
- s = −ζωₙ ± jωₙ√(1 − ζ²); ωd = ωₙ√(1 − ζ²)
- (6.2.2)
- Rise time
- tr = (π − θ)/ωd, θ = cos⁻¹ζ
- (6.2.3)
- Peak time
- tp = π/ωd
- (6.2.4)
- Peak overshoot
- Mp = e−πζ/√(1 − ζ²)
- (6.2.5)
- Settling time
- ts ≈ 4/(ζωₙ) (2%); 3/(ζωₙ) (5%)
- (6.2.6)
- First-order system
- Time constant τ; reaches 63.2% at τ; settles in ≈ 4τ
- (6.2.7)
6.3Steady-state error (unity feedback)
- Error constants
- Kp = lims→0 G; Kv = lim sG; Ka = lim s²G
- (6.3.1)
- Errors
- Step: 1/(1 + Kp); ramp: 1/Kv; parabola: 1/Ka
- (6.3.2)
- System type
- Type = number of open-loop poles at the origin
- (6.3.3)
6.4Stability
- Routh–Hurwitz
- Sign changes in the first column = number of right half-plane poles
- (6.4.1)
- Nyquist
- Z = P − N (N = anticlockwise encirclements of −1 + j0, P = open-loop RHP poles); stable iff Z = 0
- (6.4.2)
- Gain margin
- GM = 1/|GH(jωpc)| at phase −180°; GM (dB) = −20 log|GH(jωpc)|
- (6.4.3)
- Phase margin
- PM = 180° + ∠GH(jωgc) at |GH| = 1
- (6.4.4)
- PM and damping
- PM ≈ 100ζ degrees (ζ < 0.7)
- (6.4.5)
6.5Root locus
- Start and end
- Starts at open-loop poles (K = 0), ends at zeros or infinity
- (6.5.1)
- Real axis
- Locus lies left of an odd number of real poles + zeros
- (6.5.2)
- Asymptotes
- Angles (2q + 1)180°/(P − Z); centroid σ = (Σ poles − Σ zeros)/(P − Z)
- (6.5.3)
- Breakaway point
- dK/ds = 0
- (6.5.4)
- Angle of departure
- 180° − Σ∠(from other poles) + Σ∠(from zeros)
- (6.5.5)
6.6Frequency response
- Bode slopes
- Each pole −20 dB/decade and −90°; each zero +20 dB/decade and +90°
- (6.6.1)
- Resonant peak
- Mr = 1/(2ζ√(1 − ζ²)) at ωr = ωₙ√(1 − 2ζ²) (ζ < 0.707)
- (6.6.2)
- Bandwidth
- ωb = ωₙ√(1 − 2ζ² + √(4ζ⁴ − 4ζ² + 2))
- (6.6.3)
6.7Compensators and PID
- Lead compensator
- (1 + aTs)/(1 + Ts), a > 1; max lead sin φₘ = (a − 1)/(a + 1) at ωₘ = 1/(T√a)
- (6.7.1)
- Effects
- Lead: more phase margin, faster response; lag: smaller steady-state error
- (6.7.2)
- PID controller
- C(s) = Kp + Ki/s + Kd s
- (6.7.3)
- PID roles
- P speeds up; I removes steady-state error; D adds damping
- (6.7.4)
6.8State space
- Model
- ẋ = Ax + Bu; y = Cx + Du
- (6.8.1)
- Transfer function
- T(s) = C(sI − A)⁻¹B + D; poles = eigenvalues of A
- (6.8.2)
- State transition matrix
- Φ(t) = eAt = L⁻¹{(sI − A)⁻¹}
- (6.8.3)
- Solution
- x(t) = Φ(t)x(0) + ∫₀ᵗ Φ(t − τ)Bu(τ)dτ
- (6.8.4)
- Controllability
- rank[B AB … Aⁿ⁻¹B] = n
- (6.8.5)
- Observability
- rank[C; CA; …; CAⁿ⁻¹] = n
- (6.8.6)
SignalPath: free ECE roadmaps, tools and formula sheets at signalpath.pages.dev